Eltek Module Flatpack2 24V HE Rectifier Doc 241115.205.DS3 – v8
Key Features
Proven Reliability
High Efficiency (He)
Power Dense, 22 w/Inch3
Wide Temperature Range
Application Flexibility 1.8kwàMulti Cabinet Installations
Global Compliance (Ce, Ul)
Patented HE Technology
Applications
Railway & Metro
Control And Protection Power Utilities
Control And Monitoring Systems
Alarm Systems
Plc Systems
The original HE rectifier
The most efficient power conversion module in the industry! Since the launch, the Flatpack2 family has expanded into a wide selection of power ratings and voltages.
The Flatpack2 24/1800 HE is a cost efficient rectifier for 24V lead AC1D battery systems.
Specifications
Model | 24/1800 HE |
Part number | 241115.205 |
INPUT DATA | |
Voltage (nominal) | 185 - 275 VAC / 185 - 300 VDC |
Voltage (range) | 85 - 300 VAC / 85 - 300 VDC |
Frequency | 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz |
Current (maximum) @ nominal input, full load | 11.25 ADC |
Power Factor | 0.99 (@ 50-100% load) |
THD (@ 230 VAC) | < 4 % (@ full load) |
Protection | Fuse in both lines, varistor for transient protection, shutdown when VIN is out of range |
OUTPUT DATA | |
Voltage (default) | 26.75 VDC |
Voltage (adjustable range) | 21.75 - 28.8 VDC |
Max power, nominal input | 1800 W |
Max power, de-rated @VIN = 85 VDC | 750 W |
Max current, @VOUT ≤ 24 VDC | 75 A |
Hold-up time, default voltage and 1000 W load | 20 ms, VOUT > 21 VDC |
Current sharing | ± 5% of maximum current from 10 to 100% load |
Static voltage regulation (10-100% load) | ±0.5% from 10 - 100% load and supplied power not limited by PV panels |
Dynamic voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Ripple | < 250 mVPP , 30 MHz bandwidth |
Psophometric noise | < 2 mVRMS |
Protection | Overvoltage shutdown, short circuit proof, high temperature, hot plug-in inrush current limiting |
OTHER SPECIFICATIONS | |
Peak Efficiency | 95 % |
Isolation | 3 kVAC – input and output, 1.5 kVAC – input earth, 0.5 kVDC – output earth |
Alarms (Red LED) | Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
Warnings (Yellow LED) | Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
Normal (Green LED) | Input and output ok |
MTBF (Telcordia SR-332 Iss.I method III (a)) | >300 000 (@ Tambient : 25 °C) |
Operating temperature (5 - 95% RH non-cond.) | - 40 -75°C [-40 - 167°F ] |
Max output power de-rates above temp / to | 45°C [+113°F] / 1200W |
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
Dimensions[WxHxD] / Weight | 109 x 41.0 x 327mm [4.25 x 1.61 x 13"] / 1.950 kg [4.3lbs] |
DESIGN STANDARDS | |
Electrical safety | EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, IEC 60950-1:2013 UL 60950-1:2014 |
EMC | EN 61000-6-1:2007, -6-2:2005, -6-3:2007 + A1:2010, -6-4:2007 + A1:2010 IEC 61000-6-5:2015, EN 300 386:v2.1.1, FCC CFR 47 Part 15:2008 |
Environment | ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) 2011/65/EU (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised |
1) Maximum power de-rated to 1000W @230Vac & 16 2/3Hz input |